MECO

801junior

801 JUNIOR

  • 3 5/6 Digits
  • 6000 Counts
  • TRMS
  • Auto Ranging
  • DC Voltage upto 1000V
  • AC Voltage upto 750V
  • DC Current upto 10A
  • AC Current upto 10A
  • Resistance upto 60MΩ
  • Capacitance upto 100.0mF
  • Frequency upto 10.00MHz
  • Duty Cycle 1% ~ 99%
  • Temperature
  • Diode Test
  • NCV (LED, Buzzer & EF Strength)
  • Continuity Test (LED, Buzzer & EF Strength)
  • LCD with Backlight
  • Data Hold
  • Auto Power Off
  • Holster with Magnet
  • Torch Light
  • Test Lead Gripper
  • Low Battery Indication
603junior

603 JUNIOR

  • 3½ Digits
  • 2000 Counts
  • Manual Ranging
  • DC Voltage upto 1000V
  • AC Voltage upto 750V
  • DC Current upto 10A
  • AC Current upto 10A
  • Resistance upto 20MΩ
  • Diode Test
  • hFE Test (Transistor Test)
  • Continuity Test (LED, Buzzer & EF Strength)
  • NCV (LED, Buzzer & EF Strength)
  • LCD with Backlight
  • Data Hold
  • Auto Power Off
  • Holster with Magnet
  • Torch Light
  • Test Lead Gripper
  • Low Battery Indication
101B

101B+

  • 3¾ Digits
  • 4000 Counts
  • Autoranging
  • DC Voltage upto 1000V
  • AC Voltage upto 750V
  • DC Current upto 10A
  • AC Current upto 10A
  • Resistance upto 40MΩ
  • Capacitance upto 200.0µF
  • Frequency upto 10.00MHz
  • Duty Cycle 0.1% ~ 99.9%
  • Diode Test
  • Audible Continuity
  • Data Hold
  • REL Δ
  • LCD with Backlight
  • Auto Power Off
  • Low Battery Indication
108B+TMRS

108B+TRMS

  • 3 5/6 Digits
  • 6000 Counts
  • TRMS
  • Auto Ranging
  • DC Voltage upto 1000V
  • AC Voltage upto 750V
  • DC Current upto 10A
  • AC Current upto 10A
  • Resistance upto 60MΩ
  • Capacitance upto 9.999mF
  • Frequency upto 10.00MHz
  • Duty Cycle 0.1% ~ 99.9%
  • Temperature
  • Diode Test
  • Audible Continuity
  • Data Hold
  • LCD with Backlight
  • Auto Power Off
  • Low Battery Indication
153B_TMRS

153B+TMRS

  • 3 5/6 Digits
  • 6000 Counts
  • TRMS
  • Auto Ranging
  • DC Voltage upto 1000V
  • AC Voltage upto 750V
  • DC Current upto 20A
  • AC Current upto 20A
  • Resistance upto 60MΩ
  • Capacitance upto 9.999mF
  • Frequnecy 10.00MHz
  • Duty Cycle 0.1% ~ 99.9%
  • Diode Test
  • Audible Continuity
  • Data Hold
  • LCD with Backlight
  • Auto Power Off
  • Holster
  • Low Battery Indication
171B_TMRS

171B+TMRS

  • 3 5/6 Digits
  • 6000 Counts
  • TRMS
  • Auto / Manual Ranging
  • DC Voltage upto 1000V
  • AC Voltage upto 750V
  • DC Current upto 20A
  • AC Current upto 20A
  • Resistance upto 60MΩ
  • Capacitance utpo 9.999mF
  • Frequency upto 10.00MHz
  • Duty Cycle 0.1% ~ 99.9%
  • Temperature
  • Diode Test
  • Audible Continuity
  • Data Hold
  • REL Δ
  • Max / Min
  • Holster
  • LCD with Backlight
  • Auto Power Off
  • Low Battery Indiction
27TautoBL

27T-AUTO BL

  • 3½ Digits
  • 2000 Counts
  • TRMS
  • Auto Ranging
  • AC Current upto 600A
  • AC Voltage upto 600V
  • DC Voltage upto 600V
  • Resistance upto 20MΩ
  • Temperature
  • Audible Continuity
  • Diode Test
  • Data Hold
  • Max
  • Backlight Display
  • Torchlight for Clamp
  • NCV (LED, Buzzer, EF Strength)
  • Auto Power Off
  • Low Battery Indication
  • Jaw Opening : Cable Dia. 25mm (max.)
 
2502T_AutoBL

2502T-AUTO BL

  • 3½ Digits
  • 2000 Counts
  • TRMS
  • Auto / Manual Ranging
  • AC Current upto 1000A
  • AC Voltage upto 750V
  • DC Voltage upto 1000V
  • Resistance upto 20MΩ
  • Temperature
  • Audible Continuity
  • Diode Test
  • Data Hold
  • Backlight Display
  • Torchlight for Clamp
  • Max
  • NCV (LED, Buzzer & EF Strength)
  • Auto Power Off
  • Low Battery Indication
  • Jaw Opening : Cable Dia. 52mm (max.)
 
72T_AutoBL

72T-AUTO BL

  • 3¾ Digits
  • 4000 Counts
  • TRMS
  • Auto Ranging
  • AC Current upto 600A
  • AC Voltage upto 600V
  • DC Voltage upto 600V
  • Capacitance upto 200µF
  • Frequency upto 1MHz
  • Resistance upto 40MΩ
  • Temperature
  • Audible Continuity
  • Diode Test
  • Data Hold
  • Rel. Test
  • Backlight Display
  • Torchlight for Clamp
  • NCV (LED, Buzzer & EF Strength)
  • Auto Power Off
  • Low Battery Indication
  • Jaw Opening : Cable Dia. 25mm (max.)
2520thzautobl

2520THz-AUTO BL

  • 3 5/6 Digits
  • 6000 Counts
  • TRMS
  • Auto / Manual Ranging
  • AC Current upto 1000A
  • AC Voltage upto 750V
  • DC Voltage upto 1000V
  • Capacitance upto 600µF
  • Frequency upto 10MHz
  • Duty Cycle 0.1% ~ 99%
  • Resistance upto 60MΩ
  • Temperature
  • Audible Continuity
  • Diode Test
  • Data Hold
  • Backlight Display
  • Torchlight for Clamp
  • NCV (LED, Buzzer & EF Strength)
  • Auto Power Off
  • Low Battery Indication
  • Jaw Opening : Cable Dia. 52mm (max.)
 
1008TMRS

1008-TMRS

  • 3 5/6 Digits
  • 6000 Counts
  • TRMS
  • Auto / Manual Ranging
  • DC Voltage upto 1000V
  • AC Voltage upto 750V
  • DC Current upto 6000µA
  • AC Current upto 1000A
  • Resistance upto 60MΩ
  • Capacitance upto 9.999mF
  • Frequency upto 10MHz
  • Duty Cycle 0.1% ~ 99.9%
  • Temperature
  • Diode Test
  • Audible Continuity
  • Data Hold
  • Backlight Display
  • Auto Power Off
  • Low Battery Indication
  • Jaw Opening : Cable Dia. 30mm (max.)
1080TMRS

1080-TMRS

  • 3 5/6 Digits
  • 6000 Counts
  • TRMS
  • Auto / Manual Ranging
  • DC Voltage upto 1000V
  • AC Voltage upto 750V
  • DC Current upto 1200A
  • AC Current upto 1200A
  • Resistance upto 60MΩ
  • Capacitance upto 9.999mF
  • Frequency upto 10MHz
  • Duty Cycle 0.1% ~ 99.9%
  • Temperature
  • Diode Test
  • Audible Continuity
  • Data Hold
  • Backlight Display
  • Auto Power Off
  • Low Battery Indication
  • Jaw Opening : Cable Dia. 30mm (max.)
DET909

DET 909

  • Earth Resistance Range : 0 – 100 Ohms & 0 – 1000 Ohms
  • Earth Voltage : 0-10V AC
  • 3½ Digit (1999 Counts) 14mm LCD Display
  • l Auto Power Off Function (after 3-5min.)
  • l Low Battery Indication
  • l Capable of Measuring Earth Voltage (0 – 10V AC)
  • l Light Weight & Portable
  • l Extremely Simple to Operate Connect – Press – Read
  • l Designed to Reject High Levels of Noise & Interference
  • Designed to Generally Confirm to IS10656-1983
  • l Range Selection & Single Person Push Button Operation Switches
  • l Two Ranges for Earth Resistance Measurement
  • l Functions Icons on Display
  • l Battery Operated
  • l IEC 1010 CAT III 200V
  • l Sturdy, Elegant & Compact Body
PSI2016

PSI 2016

  • 3 Phase Sequence Indication via LED & Buzzer
  • Reverse Phase Indication via LED & Buzzer
  • Open Phase Indication via LED & Buzzer 
  • No Battery Required 
  • Rugged & Handy
  • Easy & Safe to Use
  • Coloured Test Probes with Heavy Duty Insulated Crocodile Clips for R, Y, B Phase Connections
  • Phase Presence Indication from as low as 60 V AC (PH-N)
LCR999A

LCR999A

  • Basic measurement accuracy 0.1% & speed upto 10 meas / sec
  • Large LCD display with bright white backlight
  • Ultra low power consumption, battery powered for 24 hours of continuous use
  • Automatic identification function (Ai).
  • Percentage display & 4 tolerance comparator : 1%, 5%, 10% & 20%
  • 9V battery & External power supply
  • Automatic correction function with datahold, max. / min. / average recording
  • Utility function configuration & current setup recovery after power off
  • Standard Mini-USB interface, SCPI compatible
  • Auto power Off
  • Constant output impedance : 100 ohm
3600+

3600+

  • 3¾ Digits
  • 4200 Counts
  • TRMS
  • Auto Ranging
  • DC Voltage upto 1000V
  • AC Voltage upto 750V
  • DC Current upto 1200A
  • AC Current upto 1000A
  • Resistance upto 40MΩ
  • Capacitance upto 40µF
  • Frequency upto 9.999MHz
  • Duty Cycle 10% ~ 90%
  • Temperature
  • Diode Test
  • Audible Continuity
  • MAX / MIN
  • Δ REL
  • Data Hold
  • Auto Power Off
  • Low Battery Indication
  • Jaw Opening : Cable Dia. 55mm (max.)
DIT918

DIT 918

  • 3½ Digit 1999 Count Large LCD Display
  • High Accuracy for Insulation Measurement and for AC Voltage Measurement
  • Range Selection & Single Person Push Button Operation
  • LCD with Indicator Switch
  • Data Holding Function, Function Icons on Display
  • Measurement of AC Voltage upto 600VAC
  • Auto Range (Insulation Test)
  • Red LED Indicator for HV (High Voltage)
  • Battery Operated
  • As per IS10656-1983
  • As per Safety Standard IEC / EN 61010-1 & 61010-31
  • Over Voltage CAT III, 600V
  • As per EMC Standard IEC 61326 Class B
DIT 954

DIT 954

  • 3½ Digit 1999 Count Large LCD Display
  • Range Selection & Single Person Push Button Operation
  • LCD with Green Backlight Function with Indicator Switch
  • Data Holding Function
  • Display with Annunciators
  • Measurement of AC Voltage upto 600VAC
  • Measurement of Phase Sequence Between (Phase – Phase Voltage) with LED Indicators & Beep Facility
  • Auto Range (Insulation Test)
  • Red LED Indicator for HV (High Voltage)
  • Inbuilt Protection Circuit to prevent the harm of reverse Voltages
  • Battery Operated with AC Adaptor
  • Suitable for Calculating PI & DAR (Manually)
  • As per EMC Standard IEC 61326-1 Class B
  • Over Voltage CAT III, 600V
  • As per Safety Standard IEC/EN 61010-1 & 61010-31
  • IP 44 Protection
4680bl

4680BL, 4680BLC

  • Non Contact Ground Resistance Measurement
  • No Auxiliary Electrodes Needed
  • Data Storing Memory
  • Data Hold, Noise Signal
  • Ground Resistance Measurement 0.01Ω ~ 1000Ω
  • Suitable for Earthing Strip of 65mm x 32mm
  • Leakage Current (0.5mA ~ 30.00A) (Model : 4680BLC)
  • Auto Ranging
  • Continuity Loop Test
  • Auto Power Off
ivcurve

IV-CURVE 9009

  • I-V Curve Test for Solar Panel / Module / Cell
  • Max. Solar Cell/Module Power / Cell Power(Pmax) search by Auto-Scan
  • Capability: 60V, 12A
  • Best Resolution: 1mV , 1mA
  • Manual Single Point I-V Test
  • Max. Voltage (Vmaxp) at Pmax
  • Max. Current (Imaxp) at Pmax
  • Voltage at Open Circuit (Vopen)
  • Current at Short Circuit (Ishort)
  • I-V Curve with Cursor to Display each Data Point
  • Efficiency (%) Calculation of Solar Panel
  • Real Time data logging
  • RS232C (to USB Bridge) Cable for PC
  • Communicate with PC via USB Cable
  • AC Adaptor and Rechargable Lithium Battery
  • Memory Size : 100 Records
  • Sampling Time of Data logging : 0 ~ 99 min
  • Large LCD with Backlight
IRT 600T

IRT 600T

  • Range : -50°C ~ 600°C (-58°F ~ 1112°F)
  • Distance Spot Ratio : 12:1
  • Emissivity : 0.1 ~ 1.0 (Adjustable)
  • °C / °F Selection
  • Laser Switch
  • Auto Power Off
  • Low Battery Indication
  • Backlight Display
PHA 5850

PHA 5850

  • Analysis of 3P4W, 3P3W, 1P2W, 1P3W Systems
  • Display of 35 Parameters in one screen (3P4W)
  • Programmable CT (1 to 600) and PT (1 to 3000) Ratios
  • RMS, PEAK Value & Crest Factor
  • True RMS value, Active Power, Apparent & Reactive Power ( KVA, KVAR)
  • Power Factor, Phase Angle ( Ф ) & Energy (WH, KWH, KVARH, PFH)
  • Average / Maximum Demand (KW, MW, KVA, MVA) with Progrmmable Period
  • Display of 50 Harmonics in one Screen with Wave form with Peak value (1024 Sample / Period)
  • Analysis of total Harmonics Destortion (THD-F)
  • Capture 28 Transient Events with Programmable Threshold (%) (DIP, SWELL & OUTAGE)
  • Built in timer & Calender for Data Logging
  • 512K Memory with Programmable interval (2 to 3000 seconds, 17000 records for 3P4W Systems)
  • Optical Isolated RS-232C ~ USB Interface
  • Calculated Unbalanced Current through Neutral line
  • Graphic Phasor Diagram
  • Facility to retrieve Power Data & Harmonics on Meter Screen
  • Software for easy download of Recorded Data & Transient events
  • Graphic Phasor Diagram
  • Facility to retrieve Power Data & Harmonics on Meter Screen
  • Software for easy download of Recorded Data & Transient events